  •  JRP234 Three Phase Smart Prepaid Meter

JRP234 Three Phase Smart Prepaid Meter

JIANGSU SUYUAN JERRY TECHNOLOGY CO., LTD    

Management innovation Product innovation satisfaction service


Welcome to inquire

Contact number:+86-527-81086617

Contact fax:0527-81086617

Contact email:Jerry_MKT@jssyjr. com



60 seconds manual response

Reply to technical advice within 30 minutes

Free 24-hour consultation service

Standard and Compliance

? IEC 62052-11: Electricity metering equipment (a.c.) – General requirements, tests and test conditions – Part 11: Metering equipment  

? IEC 62053-21: Electricity metering equipment (a.c.) – Particular requirements – Part 21: Static meter for active energy (classes 1 and 2)

? IEC 62053-23 Electricity metering equipment (a.c.) – Particular requirements – Part 23: Static meter for reactive energy (class 2&3)

? IEC 62055-41: Electricity metering – Payment systems – Part 41: Standard transfer specification (STS) - Application layer protocol for one-way token carrier systems

? DLMS/COSEM: Device Language Message Specification/Companion specification for Energy Metering

Product Features

? Dual plug-and-play communication modules application

? Large LCD to monitor meter operation

? Non-volatile memory to store meter data without using a backup battery

? Integrated STS keypad

? Sealable optical port

? Support local/remote firmware upgrade

? Terminal holes and screws with anti-dropping design

Main Functions

Measurements

? kWh/kvarh (import, export, and absolute) 

? Maximum kW/kvar demand (import, export)

? Cumulative kW/kvar demand (import, export)

? The per-phase instantaneous value of voltage, current, phase angle

? Total and per-phase instantaneous value of active power, reactive power, power factor

? Current date and time

? Frequency

? Neutral line current measurement

Billing

? Automatic monthly billing reset on 00:00:00 of the 1st day in each month, configurable

? Manual billing reset through demand reset button

? Remotely billing reset from AMI central system

? Up to 12 months of data in meter memory

Prepayment Functions

? Support online prepayment remotely from the AMI central system

? Low balance alert by audible alarm & LED alarm to remind user to top up

? Support emergency and friendly holiday mode

? STS/CTS mode switchable

? Prepaid/postpaid mode switchable

Load Profiles

? Record up to 100 days of 15-minute load profiles with 16 channels, FIFO basis

? Load profile interval configurable from 1-60 minutes

LCD display

? 8-digit LCD with three (3) decimal points for power and demand and two (2) decimal points for energy. The decimal points are programmable

? LCD size is more than 14 cm2, digit height is 10mm

? Support scrolling mode and manual mode with push button to display items

Tariff Functions

? Time of Use (TOU) measurement of import and export energies (kWh and kvarh) and import and export demands (kW and kvar) (up to 4 tariffs, 12 seasons, 12 weeks, 16 switches, 100 special days)

? Up to 32 energy tariff and 32 demand tariff registers

? Battery and supercapacitor to maintain clock and calendar

Power Quality

? Voltage unbalance

? Current reverse

? Over-voltage and under-voltage1 detection with a configurable time threshold

? Long and short outage detection with a configurable time threshold

? Over current detection with a configurable time threshold

? All power quality events will be recorded on meter memory

Anti-tamper

? Detection of meter cover, terminal and module cover open, external magnetic field, etc 

? Show tamper alarm on LCD and LED.

? All tamper events will be recorded on meter memory and sent to the AMI central system remotely

Disconnect/reconnect switch

? 3-pole internal latching relay supporting load limiting, load shedding, and prepayment function

? Remote disconnect/reconnect from AMI central system

? Scheduled disconnect/reconnect

Communication

? Full DLMS/COSEM and IEC 62056-21 compliance optical port

? MC171 for communication when there is no power

? RS485 and M-bus

? Plug-and-play PLC/RF/2G/3G/4G module

? RF/2G/3G/4G module with a supercapacitor, able to send last gasp message to AMI central system

Technical Specifications

Operating Voltage

3×230/400V

Current rating

5(100)A

Starting current

0.4% of Ib

Frequency

50Hz±5%

Accuracy Class

Active Energy: CL 1.0  1000 imp/kWh

Reactive Energy: CL 2.0  1000 imp/kvarh

Connection

L1L1L2L2L3L3NN or L1L2L3NNL3L2L1

Real-time Clock Accuracy

<3min/Year or <0.5s/Day

Impulse Voltage

withstanding capability

Electrostatic discharges (Contact discharges)

8kV

Electrostatic discharges

(Air discharges)

15kV

Fast transient burst test

4kV

Surge immunity test

6kV

Electromagnetic RF field (80MHz to 2000MHz)

10V/m(with current), 30V/m(without current)

Diameter of terminal holes

10 mm

Environment

Temperature Range: -40 °C ~ +70 °C

Humidity: Up to 95%

Protective class

II

Degree of protection

IP54

Applicable scenarios:

? Enterprises and factories.

? High-rise buildings and commercial complexes.

? High power equipment.


News you may be interested in POPULAR INFORMATION

主站蜘蛛池模板: 中国女人一级片 | 亚洲欧美清纯校园另类 | 国产在线观看精品一区二区三区 | 亚洲性色成人av | 欧美变态另类刺激 | 欧美激情aa | 亚洲综合欧美一区二区在线 | 毛片a级毛片免费播放100 | 免费黄色片一区二区 | 美女裸体黄网站18禁免费看 | 亚洲国产五月综合网 | 欧洲亚洲国产图片综合 | 99久久全国免费观看 | 久久久久亚洲ai毛片换脸星大全 | 免费看的黄色av网站 | 国产视频第一区 | www黄色免费 | 性久久久久 | 久久精品国产一区二区三 | 91精品国产高清久久久久久久久 | 亚洲精品天堂成人片AV在线播放 | 亚洲另类春色校园小说 | 99热这里只有精品18 | 日韩欧美二区 | 99视频国产精品免费观看 | 2019年最好看的中文免费视频 | 小婕子伦流澡到高潮H | 久久精品国产视频 | 老司机精品在线 | 91精品全国免费观看含羞草 | 日韩一区二区三区免费 | 激情97综合亚洲色婷婷五 | 中国少妇毛多水多 | 精品国产一区二区三区四区在线 | 国产精品免费视频一区 | 精品国产国产综合精品 | 成年人黄色影片 | av亚洲一区二区三区 | 国产高清视频在线观看一区二区 | 色偷一区国产精品 | 私人影院性盈盈影院 |